  "number": 377,
  "title": "W32Time and Kerberos: isolate the source of hybrid clock drift",
  "signal": "time source, offset and hierarchy",
  "reference": "https://learn.microsoft.com/en-us/windows-server/identity/ad-ds/manage/understand-security-identifiers",
  "decision": "Trace the forest-root PDC hierarchy, VM time integration and upstream NTP reachability; measure offsets without changing time on live DCs.",
  "pitfalls": [
    "Correct time on the collector says nothing about a remote domain controller.",
    "Two competing clock authorities can reintroduce drift after a manual correction."
  ],
  "syntheticFixtures": []
}